Ordinary pressure gauge

The ordinary pressure gauge belongs to the local indication type pressure gauge, and the pressure is displayed on the spot without the remote transmission display and adjustment function.
In the process of industrial process control and technical measurement, the general pressure gauge is more and more widely used due to the high mechanical strength of the general pressure gauge and the convenience of production and convenient reading.
Uses General pressure gauges are suitable for measuring the pressure and vacuum of liquids, gases or vapors that are non-explosive, non-crystalline, non-solidifying, non-corrosive to copper and copper alloys.
principle
The ordinary pressure gauge transmits the pressure deformation to the pointer through the elastic deformation of the sensitive component in the watch, the Bourdon tube, and then through the conversion mechanism of the movement inside the watch, causing the pointer to rotate to display the pressure.
Technical parameters of ordinary pressure gauge:
model structure type Accuracy% Measuring range MPa
Y-50
Y-50T
Y-50Z
Y-50ZQ
Radial edgeless radial belt back axial axial edgeless axial belt front ±2.5 -0.1 to 0; -0.1 to 0.06; -0.1 to 0.15;
-0.1 to 0.3; -0.1 to 0.5; -0.1 to 0.9
-0.1 to 1.5; -0.1 to 2.4; 0 to 0.16; 0 to 0.25;
0 to 0.4; 0 to 0.6; 0 to 1.0; 0 to 1.60 to 2.5;
0 to 4.0; 0 to 6.0; 0 to 10; 0 to 16; 0 to 25;
0 to 40; 0 to 60; 0 to 100
Y-60
Y-60T
Y-60Z
Y-60ZQ
Radial edgeless radial belt back axial axial edgeless axial belt front
Y-75
Y-75T
Y-75Z
Y-75ZQ
Radial edgeless radial belt back axial axial edgeless axial belt front
Y-100
Y-100T
Y-100Z
Y-100ZQ
Radial edgeless radial belt back axial axial edgeless axial belt front ±1.6
Y-150
Y-150T
Y-150Z
Y-150ZQ
Radial edgeless radial belt back axial axial edgeless axial belt front
Note: The axial direction can be squared front or clamped as required.
Operating temperature: -40 ° C ~ 70 ° C
Resistance to working environment vibration: V·H·3 level;
Relative humidity is not more than 90%;
Temperature effect: no more than 0.4% / 10 ° C (use temperature deviation of 20 ± 5 ° C);
Executive standard: GB/T1226-2001;
The external dimensions of the ordinary pressure gauge:
model Dimensions mm
A B C D d D0 M
Y-50 29 twenty four 9 50 / / G1/4
Y-50T 29 27 11 60 3.4
Y-50Z 29 twenty four 0 / /
Y-50ZQ 29 twenty four 0 60 3.4
Y-60 31 32 14 60 / / 14X1.5
Y-60T 31 32 15 75 3.4
Y-60Z 30 32 0 / /
Y-60ZQ 30 32 0 75 3.4
Y-75 twenty four 30 12 75 / /
Y-75T twenty four 30 12 90 5.5
Y-75Z twenty four 30 0 / /
Y-75ZQ twenty four 30 0 90 5.5
Y-100 44 45 18 100 / / 20X1.5
Y-100T 44 46 19 118 5.5
Y-100Z 43 45 34 / /
Y-100ZQ 43 45 44 118 5.5
Y-150 50 47 19 149 / / 20X1.5
Y-150T 50 48 20 165 5.5
Y-150Z 51 47 55 / /
Y-150ZQ 51 47 55 165 5.5
Note: The connecting thread can be ordered as required
Connection thread size
Shell nominal diameter Connector size
D d L D1
Mm Mm Mm Mm
50 M14×1.5 14 5
60 M14×1.5 14 5
75 G3/8 14 5
100 M20×1.5 20 6
150 M20×1.5 20 6
Precautions for use 1) The working pressure should be 1/3 to 2/3 of the full scale, and the maximum range of use should not exceed 3/4 of the full scale.
2) The verification period is generally not more than half a year. The medium of the pressure measurement part has large fluctuations, frequent use, high accuracy requirements, and strict requirements on safety factors. The verification period can be shortened according to the specific situation.
3) The working environment should be free of corrosive gases. 'Ordinary pressure gauge

Lighting Accessories

Led Tube,T8 Led Driver,Lighting Accessories,Led Driver Light Fixture

B-F-B-ic international Ltd.co , https://www.ledgather.com

This entry was posted in on